Studi Evaluasi Perencanaan Instalasi Penerangan Gedung Imigrasi Jakarta Utara

Penulis

  • Azhardin Taufani Teknik Elektro Institut Teknologi Nasional Bandung
  • Nasrun Hariyanto Teknik Elektro Institut Teknologi Nasional Bandung

Kata Kunci:

perencanaan, instalasi penerangan, beban lampu, kepadatan daya, planning, lighting installation, lamp load, power density

Abstrak

ABSTRAK
Gedung Imigrasi Jakarta Utara merupakan Unit Pelayanan Teknis di bidang Keimigrasian Saat penyusunan banyak perubahan yang terjadi seperti adanya penambahan jumlah titik lampu di ruangan, hal tersebut yang menjadi konsen utama penulis untuk melakukan evaluasi mengenai perencanaan ulang instalasi penerangan di area tersebut. Untuk melakukan penelitian dilakukan studi literatur dan pengumpulan data. Setelah data terkumpul, barulah penulis melakukan perhitungan jumlah titik lampu yang terpasang juga kepadatan daya dari setiap ruangan. Hasil dari penelitian ini menujukan adanya selisih antara total lampu dalam perencanaan dengan perhitungan yang dibutuhkan. total lampu terpasang sesuai dengan perencanaan berjumlah 555 buah dan jumlah lampu sesuai dengan perhitungan 2108 buah, dapat disimpulkan tingkat keberhasilan perencanaan gedung berdasarkan SNI 03-6575-2001 tentang Tata Cara Perancangan Sistem Pencahayaan Buatan Pada Bangunan Gedung sebesar 26,33 % dan perhitungan kepadatan daya terbesar pada ruang M&E sebesar 20,24 W/m2, nilai tersebut masih memenuhi standar SNI 03-6575-2001 dibawah 25 W/m2.

ABSTRACT
North Jakarta Immigration Building is a Technical Service Unit in the field of Immigration. During preparation process there is a lot of changes such as the addition of light points in each room, this is the main concern of the author to evaluate the re-planning of lighting installations in the area. To conduct the research, literature study and data collection were carried out. After the data is collected, then the author calculates total of light points installed as well as the power density of each room. The results of this study indicate that there is a difference between the total lights in the planning and the required calculations The number of lamps installed according to the plan is 555 units and the number of lamps is in accordance with the calculation of 2108 pieces, it can be concluded that the success rate of building planning based on SNI 03-6575-2001 concerning Procedures for Designing Artificial Lighting Systems in Buildings is 26.33% and the calculation of the largest power density in the M&E room of 20.24 W/m2, this value still meets the SNI standard 03-6575-2001 below 25 W/m2.

Unduhan

Diterbitkan

2022-06-14 — Diperbaharui pada 2022-07-06

Versi