Abstrak

Boilers have a very important role in power plants (XYZ). Leaks occur in the tube area, so a failure analysis needs to be carried out. In the Furniture Compartment 3 Bet Epavator area a leak occurred which caused it to fail to operate. Visual observation shows that the failure experienced by the tube experienced an eroded area due to scratches from silica sand and coal. The investigations carried out consisted of visual inspection, wall thickness measurements, penetrant coloring, hardness testing using the Vickers creep test method.

AbstrakĀ 

Boiler mempunyai salah satu peran yang sangat penting pada pembangkit listrik (XYZ). Kebocoran terjadi pada area tube, sehingga perlu dilakukan analisis kegagalan. Pada area Bet Evaporator Kompartemen Furnis 3 terjadi kebocoran yang menyebabkan gagal beroprasi. Pada pengamatan secara visual memperlihatkan bahwa kegagalan yang dialami tube tersebut mengalami area terkikis dikarenakan mengenai goresan pasir silica dan batu bara. Ivestigasi dilakukan terdiri dari inspeksi visual, pengukuran ketebalan dinding, dyepenetrant, uji kekerasan dengan metode vickers uji creep.